Abbott CELL DYN Sapphire Blood Cell Count Device

stethoscope-on-clipboard-s-710400

Abbott CELL DYN Sapphire Blood Cell Count Device

• It gives chance to work 24 parameters at a rate of 106 test/per hour through MAPSSTM laser computation and LED Flow Cell technologies.

• Volumetric Metering is recommended as an approved method by ICSH (International Committee for Standardization in Hematology).

• It ensures 5 parts leucocyte distinction by using laser scattering from 4 different points.

• It enables to work on specimen with both open and autoloader.

• Analyzing optic thrombocyte from 2 different points.

• There are quality control programmes on the device.

• Using Lyse without cyanide.

• It has capacity to save 20.000 results (including graphics) in its memory.

• Working on CD 3/4/8 and CD 61.

• FDA approved NRBC counting technology.

• The device has pneumatics unit in it.

 

 

Abbott CELL DYN Ruby Blood Cell Count Device

biochemical-research-s-710400

Abbott CELL DYN Ruby Kan Sayım Cihazı

• It gives chance to work 25 parameters at a rate of 84 test/per hour through MAPSSTM laser computation and LED Flow Cell technologies.

• It gives chance to separate all parameters with patented laser optic technology.

• Analyzing optic leucocyte from 4 different points.

• Analyzing optic erythrocyte from 4 different points.

• Analyzing optic thrombocyte from 2 different points.

• There are 6 different Scattergram and 5 different Histogram.

• Taking an opportunity to observe distinction between erythrocyte and thrombocyte with the logarithmic scattergram.

• It enables to work on specimen with both open and autoloader.

• There are quality control programmes on the device.

• Using Lyse without cyanide.

• It has capacity to save 10.000 results (including graphics) in its memory.

Abbott CELL DYN Emerald Blood Cell Count Device

biochemical-research-s-710400

Abbott CELL DYN Emerald Blood Cell Count Device

• It gives chance to work 18 parameters at a rate of 60 test/per hour through Von Behren Empedans Transduser, volumetric meterin and LED Flow Cell technologies.

• Volumetric Metering is recommended as an approved method by ICSH (International Committee for Standardization in Hematology).

• It enables to work on blood with little amount of 9,8 µL aspiration.

• There are quality control programmes on the device.

• Using Lyse without cyanide.

• It has capacity to save 10.000 results (including histograms) in its memory.

Abbott Alinity H Series

biochemical-research-s-710400

Abbott Alinity H Series